Ditel Proses bilong Kulim Oasis Bingfeng CounterflowClosed-Curcuit Cooling Tower
Wok bilong mekim kol bilongcounterflow klostu - seket bilong mekim kolrem i wanpela stretpela hat na mas transfe proses, wantaim as tingting bilong en em long maksimaisesen bilongsenis bilong hatgutpela wok long rot bilong 'countercurrent flow' bilong win na wara. Dispela em i wanpela gutpela wok painimaut bilong wok bilong mekim kol:
Fes 1: Heat Transfer (Internal Sairculation)
Hai-temperature proses wara i go insait long silimsenis bilong hatkoil sistem long rot bilong wanpela 'circulation pump'
Hat i save go insait long wol bilong paip i go ausait
Ol koil i save yusim ol samting we i save karim hat (ol kopa paip o 304 'stainless steel' paip), wantaim 'thermal conductivity' veliu bilong 401 W/m·K na 16 W/m·K wanwan

Fes 2: Pre-Kuling Fes (Drai Kondisen Operesen)
Ol 'axial fan' i save pulim win i kam long daunbilo
Win i save ron i go antap long ausait bilongsenis bilong hatol koil
Taim tempereja bilong win i daunbilo long tempereja bilong wara i go insait, ol i save mekim kol pastaim long rot bilong gutpelasenis bilong hat
Dispela hap inap long daunim hat bilong wara long 3-8 digri, i dipen long:
Tempereja bilong balb we i drai
Spit bilong win
Senis bilong hateria

Fes 3: Evaporative Cooling (Wet Kondisen Operesen)
Taim temperaja bilong ples i go antap o ol i laik mekim i kol moa, sistem i save kirapim sprei divais:
Wota Film Fomesen
Ol 'spray pam' i save tilim wara wankain long ausait bilong 'coil'
Em i kamapim wanpela wara film i go het 0.5-1mm tik
Sprei densiti i stap long 0.05-0.12 m3/(m·h)
Evaporative Heat Absorption
Win i ron long wara i save helpim wara long kamap smel
Wara i save kamap smel i save pulim hait hat bilong smel (inap olsem 2450 kJ/kg)
Dispela proses inap long rausim 70-80% bilong olgeta hat
Ol gutpela samting bilong 'counterflow'
Kolpela win i save tatsim wara we i no hat tumas
Hotpela win i save go insait long wara we i gat bikpela hat tru
Holim mak bilong tempereja we i no wankain long olgeta hap

Hap 4: Dip Kuling
Ol 'drift eliminator' i save kisim bek ol liklik wara we i stap nabaut
Ol wetpela win i save kamaut long antap
Hap 'evaporation' bilong sprei wara, wantaim wara i stap yet i go bek long koleksen besin
Otomatik sistem bilong pulimapim wara i save lukautim level bilong wara
Stretpela tempereja kontrol i kamap long rot bilong stretim sprei wara volium na win ron

Gutpela Kontrol Sistem
Ol samting bilong lukluk long taim tru:
Tempereja bilong wara i go insait/autlet (stretpela ±0.1 digri)
Tempereja na humiditi bilong ples
Sprei wara konduktiviti
Stat bilong wok bilong ol ikwipmen
Otomatik senis bilong mod:
Drai mode: temperaja bilong ples<25°C
Wet mode: ambient temperature >25 digri o tempereja difrens < set veliu
Miks mod: otomatik stretim bihainim lod

Ol mak bilong wok bilong hat
Senis bilong hatgutpela wok i kamap gutpela long 30-40% taim yumi skelim wantaim 'crossflow' disain
Tempereja bilong wara i go ausait inap long kamap long 'ambient wet-bulb temperature +3-5 degree
Footprint i go daun long moa long 25%
Eneji konsumsen i go daun long 20-30%

Data bilong aplikesen tru
Insait long wanpela kemikel plent projek, ol ikwipmen i wok aninit long 32 digri ambient tempereja na 65% relatif humiditi:
Tempereja bilong wara i go insait: 65 digri
Tempereja bilong wara i go aut: 33 digri
Tempereja i go daun: 32 digri
Wara yusim: 0.5-1% tasol bilong wara volium i raun
Pawa konsumsen: 28% daunbilo long ol tradisenel kol sistem
Dispela stretpela pasin bilong mekim kol i mekim na ol ikwipmen i wok gut aninit long ol kain kain wok kondisen na tu, ol i yusim gut ol pawa na wara risos.