tpiTok ples

Wanpela 'Evaporative Condenser' i ken wok sapos i no gat wara?

Dec 02, 2025

Larim wanpela toksave

Nogat. Wanpelaevaporative condenseri no inap wok gut sapos i no gat wara. Sapos yu fosim em long ran nating bai bagarapim ol ikwipmen.


Dispela i kamap long as tingting bilong en:

1. As tingting i dipen long wara i go aut

Namba wan rot bilong mekim wanpela 'evaporative condenser' i kol emkisim hat long rot bilong wara i kamap smellong sprei wara antap long ol 'heat exchange coils', we i save karim hat bilong 'refrigerant' i go. Sapos i no gat wara, moa long 80% bilong bikpela rot bilong rausim hat i save lus.

绿洲冰峰蒸发式冷凝器


2. Ol hevi bilong wok sapos yu no gat wara

Sapos ol i fosim ol ikwipmen long ran nating, dispela bai kamapim:

Nogat inap tru long rausim hat: Dipen tasol long liklik win konveksen(win i kol), 'heat dissipation capacity' i go daun tru, planti taim i go aninit long 20% ​​bilong mak ol i bin makim.

Sistem Hai Presa na Satdaun: Refrigerant i no inap long kondens fulwan, na dispela i mekim kondens presa bilong sistem i go antap hariap, na i kirapim ol hai-presa alarm na fosim kompresa long pasim wok bilong lukautim em.

Bagarap i stap oltaim long ol bikpela samting:

Hat tumas na drai paia bilong ol koil: Hat bilong 'high-temperature refrigerant insait long ol koil i no inap long lus, na dispela i mekim na 'metal temperature' bilong ol koil i go antap tru, na dispela i mekim na ol samting i kamap 'annealing', strong bilong ol i lus, o ol i bruk.

Bagarap long wara pam long drai ran: Sprei wara pam we i wok sapos i no gat wara bai kukim hariap ol 'mechanical seals' na 'shaft sleeve' bilong en.

绿洲冰峰闭式冷却塔

3. Skelim wantaim "Drai Operesen"Mode

Em i bikpela samting long luksave long wanpela tingting we i wankain: sampela i go antapol 'closed-circuit cooling towers'(we i wok long wankain as tingting tasol i gat narapela wok) i ken senis i go long "drai operesen" (olsem, fan tasol i wok, na sprei wara i pas) long taim bilong kol, tasol dispelai gat strongpela lo pastaim:

Tempereja bilong ples i mas stap daunbilo inap(planti taim aninit long wanpela 'wet-temperature value bilong 'bulb') bai 'sensible cooling capacity' bilong win tasol i ken inapim ol samting ol i laikim.

Koil disain i mas sanap strong long tempereja distribusen aninit long drai kondisen.

Ol 'evaporative condensers' i no save gat dispela 'mode', long wanem, ol kondisen bilong disain na presa bilong ol i strong moa.

Oasis bingfeng's Mitigation Strategies:

Long mekim sistem i stap gut long ol kastoma, ol gutpela kontrol sistem bilong mipela i gat planti samting bilong stopim ol eksiden long drai operesen:

Wota Level Intaklok Proteksen: Em i save pasim fan na wara pam long stat sapos wara bilong koleksen besin i stap daunbilo tumas.

Monitoring bilong ron na presa: I save sekim ron bilong wara bilong sprei long taim stret, na i save kirapim ol alam hariap na pasim ol samting sapos i gat ol samting i no stret.

Disain bilong lukautim wara na ais(long ol ples we i kol): Em i save rausim wara long ol paip na sprei sistem long taim bilong kol, tasol dispela em i wanpelaprotektiv drenej mesa, i no wok insait long wanpela 'drained state'.

闭式冷却塔厂家

Konklusen:

Wanpelaevaporative condenserno inap truwok nating. Em i wanpela kain "wara-driven" kol masin, we wara em i bikpela samting bilong senisim hat. Mekim gutpela, klinpela wara saplai na gutpela wara sirkulasen sistem em i nambawan samting bilong mekim wok bilong ol ikwipmen i stap gut, gutpela na longpela taim. Taim ol i makim na lukautim ol dispela kain ikwipmen, ol i mas tingim gut wok bilong disainim na lukautim gut wara sistem.

Askim wok painimaut