Olsem ol bikpela masin bilong rausim hat bilong ol indastriel frijiresen na sentral ea kondisen sistem, ol kol taua i no gat wanpela 'fixed service life', we foapela bikpela samting i save makim: kain ikwipmen, bikpela samting, wok kondisen na mentenens long olgeta de.

 

​​Compound Flow Closed Cooling Tower

 

Sevis laip bilong ol bikpela ikwipmen insait long indastri i klia. Ol ikwipmen inap long kisim sevis laip bilong en aninit long nomol operesen na mentenens, tasol sapos mentenens i no gutpela bai sotim sevis saikel bilong en. I gat bikpela spes long sevis laip namel long ol 'core wearing parts' na 'main frame', we bai yumi stori long en aninit wantaim ol wok kondisen tru.

 

 

1

taua bilong mekim kol

 

 

I gat bikpela senis long sevis laip namel long ol opol taua bilong mekim kolna ol 'closed cooling tower' long sait bilong kain straksa. Wanpela standet 'fiberglass open cooling tower' em ol i wokim bilong wok inap 15 i go inap 20 yia, na 'tower shell' bilong en i gat gutpela 'corrosion resistance'.

 

 

Compound Flow Closed Cooling Tower

 

Tasol, dispela 'fill' i save pas stret wantaim win na ol pipia longpela taim. PVC ful bai bruk na bruk bruk insait long 3 i go inap 5-pela yia tasol, na PP ful inap long skruim sevis laip i go long 6 i go inap 8 yia, na i mas senisim oltaim long mekim gutpela wok bilong senisim hat.

 

Frem bilong ol 'hot-dip galvanized steel open towers i save stap inap 10 i go inap 15 yia. Long ol ples klostu long nambis we i gat planti sol sprei na ol kemikel envairomen we i gat asid na alkali samting, 'galvanized layer' i save kisim bagarap na hul insait long 5-pela yia, na dispela i save mekim strong bilong en i go daun hariap.

 

 

2

taua bilong mekim kol

 

 

651.jpgOl 'closed cooling towers' i save bihainim wanpela 'closed coil heat exchange structure', we ol samting insait long en i no save bungim das na ol liklik binatang ausait, na dispela i save daunim tru hevi bilong korosen na 'scaling'.

 

Wanpela standet klostu kol tauawantaim 304 'stainless steel coils' i gat wanpela 'overall service life' bilong 20 i go inap 25 yia. Ol dispela i gat 316L steinles stiel i gutpela long ol kemikel na ol wok long nambis, na ol i ken wok gut inap 25 i go inap 30 yia wantaim standet mentenens.

 

 

Ol intanel sirkulating paiplain i stap klin longpela taim, na ol ekstenel sprei fil tasol i nidim klinim na senisim oltaim, na dispela i mekim bikpela mentenens saikel i go longpela moa long ol open taua.

 

 

 

 

3

taua bilong mekim kol

 

 

Fluid Cooling Heat ExchangerOl samting em i nambawan samting we i save makim hamas taim wanpela 'cooling tower' i ken stap longpela taim. Ol FRP 'fiberglass' sel i no inap long kisim asid na alkali na ol i no inap ros, na ol inap long stap 15 i go inap 20 yia aninit long ol nomol kondisen ausait.

 

 

Fluid Cooling Heat ExchangerTasol, sapos yu stap longpela taim long strongpela 'ultraviolet radiation' dispela bai kamapim 'chalking' na 'cracking'; ol sel we i no gat ol 'anti-aging coating' inap long bruk na lik bihain long 10-pela yia. Pultruded anti-corrosion fiberglass i save givim gutpela strong long san, wantaim ol gutpela model we i save givim sevis laip bilong moa long 30 yia.

 

Evaporative Cooling For Metallurgical ApplicationsHot-dip galvanized carbon steel i kam long liklik pe, na i save stap inap 10 i go inap 15 yia long ol nomol faktori wantaim klinpela wara, tasol sevis laip bilong en bai go daun stret sapos wara i no gutpela tumas wantaim planti 'chloride ions'.

 

Evaporative Cooling For Metallurgical Applications304 steinles stiel i fit long ol jenerel indastrial senario wantaim 20-25 yia sevis laip, na 316L steinles stiel i sanap aut long sol sprei na kemikel korosen resistens, na i mekim wok i stap gut long moa long 20 yia maski aninit long ol hatpela wok kondisen.

 

Desalinated Water Cooling TowerOl bikpela simen freim bilong ol indastrial 'cooling tower' i gat bikpela strong tru wantaim wanpela sevis laip bilong 30 i go inap 50 yia, na i nidim tasol senis na mentenens bilong ol 'internal fill' na 'metal pipelines' oltaim. Ol 'fan motor', 'bearing' na 'gasket' em ol samting we i save bagarap oltaim.

 

Evaporative Cooling For Metallurgical ApplicationsMaski bodi bilong taua i stap gut, ol i mas sekim o senisim ol mota long olgeta 8 i go inap 10-pela yia, na ol i mas putim 'lubricant' long ol 'bearing' long olgeta 3-pela yia; sapos nogat, nois na guria bai kamap na mekim olgeta ikwipmen i bagarap hariap.

 

4

taua bilong mekim kol

 

 

 

 

Ol kondisen bilong wok i save sotim o skruim sevis laip bilong ol ikwipmen. Ol faktori we i gat longpela taim hai-tempereja wara i go insait long en, wara i no bin klinim, bikpela das, sol sprei na kemikel pipia ges i save lukim tupela taim mak bilong korosen na skel.

 

649.jpgLongpela taim wok wantaim strongpela wara i save kamapim tikpela 'limescale' long ol 'coil' na 'fills', we i save daunim 'heat exchange efficiency' na i save kirapim 'local stress corrosion'. Ol 'chloride ions' we i kam long ol kemikel pipia ges na win bilong solwara long nambis i save bagarapim ol metal komponen.

 

Ol 'cooling tower' we i no gat ol 'water chemical dosing' na 'side filtration system' bai lusim wanpela hap bilong laip bilong ol. Tasol, ol 'indoor facilities' o ol nomol faktori we i gat gutpela kwaliti bilong wara, gutpela tempereja bilong wara na klinpela ples i save lukim ol ikwipmen i no save bagarap hariap, na planti ol yunit inap long winim o winim sevis laip bilong ol.

 

 

 

5

taua bilong mekim kol

 

Mentenens long olgeta de em i bikpela samting long winim sevis laip we ol i makim, na sapos ol i no lukautim gut dispela bai mekim ol ikwipmen i bagarap hariap. Standet mentenens i gat foapela modul: wara kwaliti kontrol, klinim oltaim, straksel anti-korosen na sisen proteksen.

 

Loaded Unit Photographs Closed-Circuit Cooling Tower Ready for Dispatch.jpg

 

Ol i mas sekim pH veliu na hat bilong wara long olgeta mun, ol i mas givim ol 'scale' na 'corrosion inhibitors', na ol i mas mekim 'blowdown' oltaim long daunim 'concentration ratio'. Ol i mas wasim ol 'fil', rausim ol 'slag' insait long ol wara besin na rausim ol 'spray nozzle' long olgeta kwata.

 

Ol i mas sekim ol ain straksa long rausim ros na penim gen, na ol i mas stretim ol bruk long ol sel bilong 'fiberglass' long olgeta yia. Ol i mas rausim wara i stap yet na putim 'antifreeze' long taim bilong kol long stopim paiplain long bruk.

 

Sapos yu no klinim longpela taim, dispela bai pasim 'fill', 'motor overload' na 'frame corrosion perforation'. Ol 'fiberglass open towers' we i gat 15-yia disain laip bilong en i ken nidim ful riplesmen insait long 8-pela yia aninit long ol hevi wok kondisen.

 

6

taua bilong mekim kol

 

 

 

Folem ol wok bilong indastriel enjiniaring, standet sevis laip bilong ol standet konfigurasen insait long ol jenerel faktori em olsem: ol 'fiberglass open cooling towers' we ol i lukautim gut inap long wok inap 12 i go inap 18 yia, na ol 'hot-dip galvanized steel open towers inap long wok inap 8 i go inap 15 yia; ol 'closed cooling towers' wantaim 304 'stainless steel coils' i save wok gut inap 20 i go inap 25 yia, na ol 'anti-corrosion closed towers' we i yusim 316L 'stainless steel' i save wok gut inap 25 i go inap 30 yia.

 

 

Customer Site Installation of Closed-Circuit Cooling Tower.jpg

 

 

Taim ol i mekim ol disisen long baim ol samting, ol baia i no ken lukluk tasol long namba wan pe bilong baim samting. Ol samting we i stret wantaim sevis envairomen bai ol i makim wantaim ol standet mentenens plen. Dispela i no inap long mekim sevis saikel bilong ol ikwipmen i stap longpela taim tasol, tasol tu i ken katim ol bikpela kos we i save kamap long senisim ol ikwipmen planti taim na pasim mentenens.

Askim wok painimaut