Ol 'Cooling Towers' we i pas i mas kisim wara planti taim taim ol i wok?
Apr 14, 2026
Larim wanpela toksave
Ol 'closed cooling towers' em ol i save yusim planti long ol indastrial 'cooling systems'.
Planti yusa i wari long wanpela askim long wok tru: ol i nidim wara planti taim long taim bilong wok?
Hamas taim na hamas taim ol i mas putim wara gen i dipen long ol wok, ol samting i stap long envairomen, wok bilong lukautim gut wara, na pasin bilong pasim ol ikwipmen.

Ansa em olsem ol 'cooling tower' we i pas i mas kisim wara oltaim, tasol i no olsem ol i mas pulimapim wara planti taim na planti taim.
Sapos ol i wokim gut na lukautim gut dispela sistem, orait ol i ken bosim wara yu yusim insait long gutpela mak.
Wara i lus insait long ol 'closed cooling tower' i save kamap long 4-pela samting: lus bilong hat, lus bilong win, lus bilong win, na liklik lik bilong sistem. Namel long ol, lus bilong 'evaporation' em i nambawan samting na yumi no inap abrusim.Ol 'cooling tower' i pasrausim hat long rot bilong rausim wara bilong sprei ausait long pes bilong koil.
Long taim bilong 'evaporation', wara i save tanim i go long 'vapor' na i go insait long win, na dispela volium i mas kisim wara gen. Aninit long ol nomol kondisen, lus bilong 'evaporation' i save kamapim samting olsem 1% i go inap 2% bilong wara i ron. Bikpela lod, bikpela temperaja bilong ples, na liklik humiditi i save kamapim bikpela 'evaporation' na tu bikpela askim bilong wara.
Namba tu em win drif lus. Antap bilong wanpelaklostu 'cooling tower' i gat wanpela fen we i save kamapim win i go antap taim em i wok, na dispela i save karim ol liklik wara i go aut long taua, na dispela i save mekim wara i lus. Ol gutpela 'closed cooling tower' i gat ol 'water eliminator' na 'baffles' bilong daunim 'drift loss', we ol i ken bosim insait long 0.1% bilong 'circulating water flow'. Olpela, bagarap, o rong instalesen bilong ol wara eliminata bai mekim 'drift loss' i go antap na mekim wara i pulap gen planti taim.

Namba tri hap em 'blowdown loss', ol i save kolim tu olsem 'blowdown flow'. Long stopim 'concentration' bilong 'calcium' na 'magnesium ions' insait long wara we i raun bihain long em i kamap 'evaporation' planti taim, we i save kamapim 'scaling', 'corrosion', na 'microbial growth', sistem i nidim 'blowdown' oltaim long rausim ol 'high-concentration wastewater na pulapim gen fres wara. Volium bilong 'blowdown' i save kamap long ol 'cycles' bilong 'concentration';ol bikpela saikel i min olsem liklik pairapna liklik wara i pulap gen. Gutpela wara tritmen na otomatik blowdown kontrol inap long daunim tru wara i no gat wok long pulimapim.

Laspela, sistem lik lus i save kamap long liklik 'seepage' i kam long ol 'spray pipe joints', wara besin, 'valve', 'flanges', na ol narapela samting, we i no save kamap planti taim. Tasol, sapos ol bruk i kamap long wara besin, ol 'seal' i go lapun, o ol paiplain i bruk, 'leak' bai go antap tru, na dispela bai mekim wara i pulap gen planti taim nai nidim mentenens long taim stret.


Long tok sot, ol 'closed cooling towers' i nidim liklik '-' wara long taim ol i wok yet, tasol ol 'intermittent' wok i nidim wanpela 'refill' tasol taim ol i stat. Wara konsumsen i save go antap tru long taim bilong bikpela -temperature, ful-lod long taim bilong san na i save go daun tru long taim bilong low-lod long taim bilong kol. Sotpela taim sot bilong wara we i nidim planti taim em i no save kamap stret, planti taim dispela i save kamap bikos ol samting bilong rausim wara i bagarap, ol 'blowdown valve' i no pas gut, ol wara besin i lik, o ol paiplain i bruk.

Long wok bilong olgeta de, ol samting olsem skruim ol 'cycles' bilong 'concentration', putim ol 'automatic makeup valves', sekim ol 'sealing structures' oltaim, nastretim ol lik hariapinap long bosim gut wara yu yusim. Long olgeta, ol 'closed cooling tower' i no gat planti wara lus na gutpela wok bilong sevim wara winim ol 'open cooling tower'. Sapos ol i lukautim gut, ol i no nidim planti wara long han, na ol otomatik wara saplai divais inap long sapotim gutpela wok.
Askim wok painimaut





